Recall reference / CPSC 14-114

Genie PowerMax and TriloG recall 14-114: serial-prefix identification

The 2014 CPSC notice applies to specified PowerMax 1200/1500 and TriloG 1200/1500 screw-drive openers only when their serial-prefix group matches. Compare the first five serial digits with the correct Genie or Genie Pro column before treating a unit as affected.

Start with the issuer’s notice.

U.S. Consumer Product Safety Commission: Genie Recalls Garage Door Openers Due to Fire Hazard

Recall number: 14-114 · Notice date: 2014-02-25

Issuer scope: Four named marketing models and their separate five-digit Genie/Genie Pro serial-prefix lists. Naming a model alone does not establish that every unit is recalled.

Published remedy: For affected units, the CPSC notice instructs consumers to stop using and unplug the opener and contact Genie for the recall repair kit. Contact the recalling firm for the current recall process.

Match the equipment details below and follow the issuer’s current recall process. This reference does not establish the present availability of a remedy or replace the original notice.

Identification details & limits

Reference identifier: CPSC 14-114. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.

  • CPSC recall 14114RecallID=1629; Description; Hazards; Remedies · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
  • CPSC table 14114Recall Details > serial-number table; separate Genie and Genie Pro columns · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission
Identification and scope details from the cited sources; each row retains its source locator.
Recall number14-114
  • CPSC recall 14114RecallNumber · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
HazardThe control board can overheat, posing a fire hazard.
  • CPSC recall 14114Hazards · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
Affected scopeFour named marketing models and their separate five-digit Genie/Genie Pro serial-prefix lists. Naming a model alone does not establish that every unit is recalled.
  • CPSC recall 14114Description · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
Published remedyFor affected units, the CPSC notice instructs consumers to stop using and unplug the opener and contact Genie for the recall repair kit. Contact the recalling firm for the current recall process.
  • CPSC recall 14114Description and Remedies · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
Genie / PowerMax serial prefixes11214, 11347, 11215, 11348, 11235, 12006, 11256, 12009, 11298, 12018, 11311, 12019, 11312, 12026, 11313, 12027, 11326, 12034, 11327, 12036, 11336, 12037, 11332, 12038, 12058
  • CPSC table 14114Table body columns 1 and 2; five-digit prefixes · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission
Genie Pro / TriloG serial prefixes11214, 11313, 11332, 11336, 11347, 11348, 11349
  • CPSC table 14114Table body column 3; five-digit prefixes · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission

Equipment named in the source scope

These statements preserve the issuer’s exact limits. A listed name alone does not establish that every unit in the model family is affected.

  • PowerMax 1200

    Conditional coverage under CPSC 14-114: Applies only to the Genie PowerMax 1200 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11347, 11215, 11348, 11235, 12006, 11256, 12009, 11298, 12018, 11311, 12019, 11312, 12026, 11313, 12027, 11326, 12034, 11327, 12036, 11336, 12037, 11332, 12038, 12058. Check the exact label against the official notice. No statement about other models or serial prefixes.

    Applies only within this source scope
    • Market: US
    • Model scope: PowerMax 1200
    • Applies only to the Genie PowerMax 1200 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11347, 11215, 11348, 11235, 12006, 11256, 12009, 11298, 12018, 11311, 12019, 11312, 12026, 11313, 12027, 11326, 12034, 11327, 12036, 11336, 12037, 11332, 12038, 12058.
    • Check the exact label against the official notice. No statement about other models or serial prefixes.
    • CPSC recall 14114Description, named models and product type · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
    • CPSC table 14114Genie Serial Number column(s) · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission
  • PowerMax 1500

    Conditional coverage under CPSC 14-114: Applies only to the Genie PowerMax 1500 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11347, 11215, 11348, 11235, 12006, 11256, 12009, 11298, 12018, 11311, 12019, 11312, 12026, 11313, 12027, 11326, 12034, 11327, 12036, 11336, 12037, 11332, 12038, 12058. Check the exact label against the official notice. No statement about other models or serial prefixes.

    Applies only within this source scope
    • Market: US
    • Model scope: PowerMax 1500
    • Applies only to the Genie PowerMax 1500 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11347, 11215, 11348, 11235, 12006, 11256, 12009, 11298, 12018, 11311, 12019, 11312, 12026, 11313, 12027, 11326, 12034, 11327, 12036, 11336, 12037, 11332, 12038, 12058.
    • Check the exact label against the official notice. No statement about other models or serial prefixes.
    • CPSC recall 14114Description, named models and product type · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
    • CPSC table 14114Genie Serial Number column(s) · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission
  • TriloG 1200

    Conditional coverage under CPSC 14-114: Applies only to the Genie Pro TriloG 1200 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11313, 11332, 11336, 11347, 11348, 11349. Check the exact label against the official notice. No statement about other models or serial prefixes.

    Applies only within this source scope
    • Market: US
    • Model scope: TriloG 1200
    • Applies only to the Genie Pro TriloG 1200 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11313, 11332, 11336, 11347, 11348, 11349.
    • Check the exact label against the official notice. No statement about other models or serial prefixes.
    • CPSC recall 14114Description, named models and product type · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
    • CPSC table 14114Genie Pro Serial Number column(s) · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission
  • TriloG 1500

    Conditional coverage under CPSC 14-114: Applies only to the Genie Pro TriloG 1500 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11313, 11332, 11336, 11347, 11348, 11349. Check the exact label against the official notice. No statement about other models or serial prefixes.

    Applies only within this source scope
    • Market: US
    • Model scope: TriloG 1500
    • Applies only to the Genie Pro TriloG 1500 screw-drive opener with one of these first-five-digit serial prefixes: 11214, 11313, 11332, 11336, 11347, 11348, 11349.
    • Check the exact label against the official notice. No statement about other models or serial prefixes.
    • CPSC recall 14114Description, named models and product type · checked 2026-09-11 · Recall API snapshot · U.S. Consumer Product Safety Commission
    • CPSC table 14114Genie Pro Serial Number column(s) · checked 2026-09-11 · Official notice HTML snapshot · U.S. Consumer Product Safety Commission

Sources & review dates

  1. CPSC recall 14114U.S. Consumer Product Safety Commission · US · checked 2026-09-11 · Recall API snapshot
  2. CPSC table 14114U.S. Consumer Product Safety Commission · US · checked 2026-09-11 · Official notice HTML snapshot

This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.

The issuer’s notice defines its own scope and remedy. Anderson’s repair service covers its listed Connecticut communities; this national reference does not imply nationwide service.

Call (203) 902-3902 — Check Today's Availability