Equipment reference / 0-499-038* 0-499-037* 0-553-099
Rytec Fast-Fold pneumatic panels: side tubes, ties and an unresolved nut size
Retain the four panel positions, rope-tie versus sealed choices, and the malformed tee-nut specification.
Identification details & limits
Reference identifier: 0-499-038* 0-499-037* 0-553-099. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.
| Item 1: 0-499-038* | Dimension-dependent left side-tube weldment. Source-table quantity: 1. The asterisk marks a manufactured-size-dependent reference. Obtain the configured ordering number using the door serial.
|
|---|---|
| Item 2: 0-009-618 | Panel-side retainer. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Item 3: 0-551-041 | Self-tapping fastener, 1/4-20 by 1 in. Source-table quantity: as required or unspecified.Sources for this componentDescription and scope
Exact identifier
|
| Item 4: 0-499-162* | Dimension-dependent side seal. Source-table quantity: 2. The asterisk marks a manufactured-size-dependent reference. Obtain the configured ordering number using the door serial.
|
| Item 5: 0-553-104 | Serrated-flange nut, 5/16-18. Source-table quantity: as required or unspecified.Sources for this componentDescription and scope
Exact identifier
|
| Item 6: unnumbered selection | Factory-selected left Puralon panel for rope-tie version. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 6: unnumbered selection | Factory-selected left Puralon panel for sealed version; unillustrated. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 7: 0-499-050 | Side-arm clamping flange. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Item 8: unnumbered selection | Factory-selected left-center Puralon panel for rope-tie version. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 8: unnumbered selection | Factory-selected left-center Puralon panel for sealed version; unillustrated. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 9: 0-499-051 | Center-arm clamping flange. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Item 10: unnumbered selection | Factory-selected right-center Puralon panel for sealed version. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 10: unnumbered selection | Factory-selected right-center Puralon panel for rope-tie version; unillustrated. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 11: unnumbered selection | Factory-selected right Puralon panel for sealed version. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 11: unnumbered selection | Factory-selected right Puralon panel for rope-tie version; unillustrated. Source-table quantity: 1. No fixed part number is provided; preserve the factory or unnumbered selection.
|
| Item 12: 0-499-037* | Dimension-dependent right side-tube weldment. Source-table quantity: 1. The asterisk marks a manufactured-size-dependent reference. Obtain the configured ordering number using the door serial.
|
| Item 13: 0-550-198 | Serrated-flange fastener, 1/2 by 0.75 in; thread pitch omitted here. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Item 14: 0-550-290 | Slotted fastener, 1/4-20 by 0.5 in. Source-table quantity: 6.Sources for this componentDescription and scope
Exact identifier
|
| Item 15: 0-205-001 | UHMW wear strip. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Item 16: 0-407-304* | Dimension-dependent seal. Source-table quantity: 2. The asterisk marks a manufactured-size-dependent reference. Obtain the configured ordering number using the door serial.
|
| Item 17: 0-007-140 | Panel tie rope. Source-table quantity: as required or unspecified.Sources for this componentDescription and scope
Exact identifier
|
| Item 18: 0-004-181 | Rope crimp fitting. Source-table quantity: as required or unspecified.Sources for this componentDescription and scope
Exact identifier
|
| Item 19: 0-107-120 | PVC tie knob. Source-table quantity: as required or unspecified.Sources for this componentDescription and scope
Exact identifier
|
| Item 20: 0-553-099 | Tee nut withmalformed14/20 specification; hold thread size. Source-table quantity: 6. The printed thread specification is malformed; no new exact part selection or fitment relationship is approved.
|
| Serial and revision scope | Fast-Fold pneumatic configuration, R0415238, revision February 23, 2006. Confirm the door serial and installed equipment with Rytec. Special engineering and later changes can alter fitted parts. This historical identification reference supplies no current availability, replacement successor or installation procedure.
|
| Selection boundary | 0-553-099 is printed with the malformed thread text 14/20. Hold the thread specification and exact selection rather than silently changing it to 1/4-20. Factory-selected Puralon panels and starred side tubes require the door dimensions and serial. Hyphenated 0-007-140, 0-004-181 and 0-107-120 are not automatically aliases of condensed numbers in other manuals.
|
| Rope-tie height scope | The pneumatic table covers 6–12-foot doors. It specifies two tie rows through 11 feet and three at 12 feet. Do not extend the separate electric Fast-Fold table through 20 feet to this pneumatic version.
|
| Upper seal and timer identification | The factory-fitted upper seal is held at the back of the head with a U-clip. Timer appearance may differ from the pictured example, so the photograph cannot identify a replacement timer.
|
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: Rytec Fast-Fold pneumatic panels: side tubes, ties and an unresolved nut size · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-009-618 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 27 / printed page 23: 0-551-041 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-553-104 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-499-050 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-499-051 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 29 / printed page 25: 0-550-198 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-550-290 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-205-001 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-007-140 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-004-181 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast-Fold pneumatic manual, February 23, 2006R0415238, February 23, 2006, PDF page 33 / printed page 29: 0-107-120 · checked 2026-09-13 · R0415238, February 23, 2006 · Rytec
- Rytec Fast Fold Pneumatic Door installation manualR0415239 January 26, 2006, PDF page 15 / printed page 11: Rope-tie height scope · checked 2026-09-13 · R0415239 January 26, 2006 · Rytec
- Rytec Fast Fold Pneumatic Door installation manualR0415239 January 26, 2006, PDF page 23 / printed page 19: Upper seal and timer identification · checked 2026-09-13 · R0415239 January 26, 2006 · Rytec
Sources & review dates
- Rytec Fast-Fold pneumatic manual, February 23, 2006Rytec · US · checked 2026-09-13 · R0415238, February 23, 2006
- Rytec Fast Fold Pneumatic Door installation manualRytec · US · checked 2026-09-13 · R0415239 January 26, 2006
This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.
The cited sources define the product details shown here; comparison does not establish fitment.