Equipment reference / Rytec Pharma-Seal right column: transmitter and bracket height choices

Rytec Pharma-Seal right column: transmitter and bracket height choices

Match the listed 2000, 2400 and 2800 mm transmitter selections to their separately listed right mounting brackets.

Identification details & limits

Reference identifier: Rytec Pharma-Seal right column: transmitter and bracket height choices. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.

Identification and scope details from the cited sources; each row retains its source locator.
Item -: R1100163-2X*Right straight low-profile column assembly. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 1: RPR990004*Right straight low-profile column weldment. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
Exact component numberRPR990012
Exact-number source traceRPR990012
Item 2: RPR990012Right top-plate weldment. Source-table quantity: 1.
Item 3: RPR990030Hood-bracket weldment, unstarred here. Source-table quantity: 1. Exact selection is unresolved because of conflicting role, dimension, prefix or serial-dependent designation. Confirm the actual part with Rytec.
Item 4: RPR990006*Right column-cover assembly. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
Exact component numberRPR030004
Exact-number source traceRPR030004
Item 5: RPR030004Non-drive drum mounting plate. Source-table quantity: 1.
Item 6: RPR020090*Right transmitter mounting bracket, Telco 2000 mm. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 6: RPR020091*Right transmitter mounting bracket, Telco 2400 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 6: RPR020092*Right transmitter mounting bracket, Telco 2800 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 7: RPR990078*Telco transmitter, 2000 mm. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 7: RPR990079*Telco transmitter, 2400 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 7: RPR990080*Telco transmitter, 2800 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
Item 10: RPR990081*Counterweight assembly. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
Exact component numberRPR990029
Exact-number source traceRPR990029
Item 11: RPR990029Counterweight-strap idler-roller assembly. Source-table quantity: 1.
Exact component numberRPR030013
Exact-number source traceRPR030013
Item 12: RPR030013Idler-roller pin. Source-table quantity: 1.
Exact component numberRPR020024
Exact-number source traceRPR020024
Item 13: RPR020024Idler-pin plate. Source-table quantity: 1.
Exact component numberRS553103
Exact-number source traceRS553103
Item 14: RS5531031/4-20 UNC serrated-flange nut; description ends after flange fragment. Source-table quantity: 11.
Exact component numberR0550330
Exact-number source traceR0550330
Item 15: R05503303/8-16 by 1 inch bolt. Source-table quantity: 3.
Exact component numberR021793
Exact-number source traceR021793
Item 16: R0217931/4-20 UNC by 1.5 inch screw. Source-table quantity: 1.
Exact component numberRS021794
Exact-number source traceRS021794
Item 17: RS0217941/4-20 UNC stainless jam nut. Source-table quantity: 1.
Exact component numberR0550016
Exact-number source traceR0550016
Item 18: R05500161/4-20 by 3/4 inch zinc GR5.2 HFSMS screw. Source-table quantity: 4.
Exact component numberR0021048
Exact-number source traceR0021048
Item 19: R00210481/4-20 by 1/2 inch zinc GR5.2 HFSMS screw. Source-table quantity: 2.
Item 20: RS0217971/4-20 UNC by 3/4 inch Phillips truss-head screw. Source-table quantity: 4. Exact selection is unresolved because of conflicting role, dimension, prefix or serial-dependent designation. Confirm the actual part with Rytec.
Exact component numberR0904030
Exact-number source traceR0904030
Item 21: R0904030Cable clip, 3/8 inch inside diameter. Source-table quantity: 2.
Serial and revision scopePharma Seal, RPR150001, revision December 29, 2014. Confirm the door serial and installed configuration with Rytec; customized engineering and later changes can alter fitted parts. This historical identification reference establishes no current availability, successor or installation procedure.
Selection boundaryRPR990078*, RPR990079* and RPR990080* are the transmitter alternatives; RPR020090*, RPR020091* and RPR020092* are the corresponding labelled bracket-height alternatives. Serial-dependent references do not become fixed graph endpoints. The counterweight is RPR990081*, and its separate front/rear breakdown does not supply one universal weight. No transmitter-to-receiver or whole-door fitment is inferred.

Sources & review dates

  1. Rytec Fast-Seal owner manual, current 17-inch link with mixed column-size partsRytec · US · checked 2026-09-13 · AD (2021-03-24), R0215002
  2. Rytec Pharma Seal manual, December 29, 2014Rytec · US · checked 2026-09-13 · RPR150001, December 29, 2014

This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.

The cited sources define the product details shown here; comparison does not establish fitment. Anderson’s repair service covers its listed Connecticut communities; this national reference does not imply nationwide service.

Call (203) 902-3902 — Check Today's Availability