Equipment reference / Rytec Pharma-Seal right column: transmitter and bracket height choices
Rytec Pharma-Seal right column: transmitter and bracket height choices
Match the listed 2000, 2400 and 2800 mm transmitter selections to their separately listed right mounting brackets.
Identification details & limits
Reference identifier: Rytec Pharma-Seal right column: transmitter and bracket height choices. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.
| Item -: R1100163-2X* | Right straight low-profile column assembly. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
|---|---|
| Item 1: RPR990004* | Right straight low-profile column weldment. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 2: RPR990012 | Right top-plate weldment. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 3: RPR990030 | Hood-bracket weldment, unstarred here. Source-table quantity: 1. Exact selection is unresolved because of conflicting role, dimension, prefix or serial-dependent designation. Confirm the actual part with Rytec.
|
| Item 4: RPR990006* | Right column-cover assembly. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 5: RPR030004 | Non-drive drum mounting plate. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 6: RPR020090* | Right transmitter mounting bracket, Telco 2000 mm. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 6: RPR020091* | Right transmitter mounting bracket, Telco 2400 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 6: RPR020092* | Right transmitter mounting bracket, Telco 2800 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 7: RPR990078* | Telco transmitter, 2000 mm. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 7: RPR990079* | Telco transmitter, 2400 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 7: RPR990080* | Telco transmitter, 2800 mm. Source-table quantity: unspecified or as required. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 10: RPR990081* | Counterweight assembly. Source-table quantity: 1. This is a serial-dependent ordering reference, not a universal fixed SKU.
|
| Item 11: RPR990029 | Counterweight-strap idler-roller assembly. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 12: RPR030013 | Idler-roller pin. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 13: RPR020024 | Idler-pin plate. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 14: RS553103 | 1/4-20 UNC serrated-flange nut; description ends after flange fragment. Source-table quantity: 11.Sources for this componentDescription and scope
Exact identifier
|
| Item 15: R0550330 | 3/8-16 by 1 inch bolt. Source-table quantity: 3.Sources for this componentDescription and scope
Exact identifier
|
| Item 16: R021793 | 1/4-20 UNC by 1.5 inch screw. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 17: RS021794 | 1/4-20 UNC stainless jam nut. Source-table quantity: 1.Sources for this componentDescription and scope
Exact identifier
|
| Item 18: R0550016 | 1/4-20 by 3/4 inch zinc GR5.2 HFSMS screw. Source-table quantity: 4.Sources for this componentDescription and scope
Exact identifier
|
| Item 19: R0021048 | 1/4-20 by 1/2 inch zinc GR5.2 HFSMS screw. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Item 20: RS021797 | 1/4-20 UNC by 3/4 inch Phillips truss-head screw. Source-table quantity: 4. Exact selection is unresolved because of conflicting role, dimension, prefix or serial-dependent designation. Confirm the actual part with Rytec.
|
| Item 21: R0904030 | Cable clip, 3/8 inch inside diameter. Source-table quantity: 2.Sources for this componentDescription and scope
Exact identifier
|
| Serial and revision scope | Pharma Seal, RPR150001, revision December 29, 2014. Confirm the door serial and installed configuration with Rytec; customized engineering and later changes can alter fitted parts. This historical identification reference establishes no current availability, successor or installation procedure.
|
| Selection boundary | RPR990078*, RPR990079* and RPR990080* are the transmitter alternatives; RPR020090*, RPR020091* and RPR020092* are the corresponding labelled bracket-height alternatives. Serial-dependent references do not become fixed graph endpoints. The counterweight is RPR990081*, and its separate front/rear breakdown does not supply one universal weight. No transmitter-to-receiver or whole-door fitment is inferred.
|
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: Rytec Pharma-Seal right column: transmitter and bracket height choices · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: RPR990012 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: RPR030004 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: RPR990029 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: RPR030013 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: RPR020024 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 28 / printed page 22: RS553103 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 30 / printed page 24: R0550330 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: R021793 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: RS021794 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Fast-Seal owner manual, current 17-inch link with mixed column-size partsR0215002 Rev AD (2021-03-24), PDF page 49, printed page 42: Rendered label R0550016 · checked 2026-09-13 · AD (2021-03-24), R0215002 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: R0021048 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
- Rytec Pharma Seal manual, December 29, 2014RPR150001, December 29, 2014, PDF page 38 / printed page 32: R0904030 · checked 2026-09-13 · RPR150001, December 29, 2014 · Rytec
Sources & review dates
- Rytec Fast-Seal owner manual, current 17-inch link with mixed column-size partsRytec · US · checked 2026-09-13 · AD (2021-03-24), R0215002
- Rytec Pharma Seal manual, December 29, 2014Rytec · US · checked 2026-09-13 · RPR150001, December 29, 2014
This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.
The cited sources define the product details shown here; comparison does not establish fitment.