Identification details & limits

Reference identifier: Powerhouse XL Jazz PLC: controller and alarm-message identification. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.

Identification and scope details from the cited sources; each row retains its source locator.
Document scopeRytec document 1600614-0, December 10, 2012, covers the Jazz PLC Powerhouse XL Dual Drive Door. It does not identify every Powerhouse XL controller configuration.
Controller identityThe described arrangement uses a Unitronics Jazz PLC for two motors. This source does not establish an exact Unitronics submodel or a Rytec ordering number.
Individual schematicUse the control-panel schematic supplied for the individual door. The manual illustrations and general input/output description do not prove accessory fitment.
Read the messageA yellow pushbutton lamp accompanies an alarm, and the displayed message distinguishes the condition. A reset is not proof that the underlying fault is repaired.
Safety Limits and PhotocellSafety Limits concerns travel beyond the primary sensing point toward a backup limit; Photocell concerns the photo-eye circuit. The manual calls for repair before operation with these faults.
Chain Hoist RH/LHThis message concerns the manual-hoist interlock on the displayed side. It describes a different circuit role from a chain proximity sensor.
Chain Sensor RH/LHThese messages concern the drive-chain proximity sensors in the emergency-stop circuit, one for each side in the described dual-drive arrangement. No exact sensor part number is supplied.
Load Sensor RH/LHThese messages concern excessive power consumption. The described arrangement has four overload devices, two per motor; the alarm name does not identify a replacement part.
Wireless EdgeThis message concerns the bottom-bar reversing-edge system, including communication and battery checks. The section supplies no exact radio, receiver or battery ordering number.
Screenshot numbers are not fault-code identitiesThe same example value 0000116 appears beside Photocell and Chain Hoist LH. Do not use it as a unique error-code or part-number lookup.
Message and side remain essentialOther illustrations show 0000115 through 0000118 beside chain/load messages; page 14 repeats 0000116 beside Wireless Edge. Preserve the message text and RH/LH side instead of inventing a numeric-code table.
Selection boundaryMatch the door serial, installed controller and individual schematic with qualified service support. This historical identification aid provides no programming, reset, force-setting, bypass or electrical repair procedure.

Sources & review dates

  1. Jazz PLC Powerhouse XL Dual Drive Door Operating InstructionsRytec · US · checked 2026-09-13 · 1600614-0 December 10, 2012

This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.

The cited sources define the product details shown here; comparison does not establish fitment. Anderson’s repair service covers its listed Connecticut communities; this national reference does not imply nationwide service.

Call (203) 902-3902 — Check Today's Availability