Equipment reference / Turbo-Seal Insulated Gen2 blowers: selection above and below 16ft

Turbo-Seal Insulated Gen2 blowers: selection above and below 16ft

Compare the two opening-height arrangements, their exact mounting hardware and the blower references that need factory identification.

Identification details & limits

Reference identifier: Turbo-Seal Insulated Gen2 blowers: selection above and below 16ft. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.

Identification and scope details from the cited sources; each row retains its source locator.
Selection boundaryOpening height at most 16ft only. Complete blower and Uni-Strut beam have X suffixes. R0550261 flange screw at blower andR0551261 support screw are distinct printed references; no numeric repair. Blower spacing depends on opening width.
R1170530-0XBlack blower assembly — Serial-configured or incomplete reference.
Referenced part numberR1170530-0X
R0014267Blower power cord — Listed component.
Sources for this component

Description and scope

Exact identifier

R00216031/4-20x.375in flanged screw — Listed component.
Sources for this component

Description and scope

Exact identifier

R1170533-0Blower — Listed component.
Sources for this component

Description and scope

Exact identifier

R5550241-0Z013/8-16 Uni-Strut nut — Listed component.
Sources for this component

Description and scope

Exact identifier

R05502613/8-16x 1.25in flanged blower mounting screw — Listed component.
Sources for this component

Description and scope

Exact identifier

R05551463/8in flat washer — Listed component.
Sources for this component

Description and scope

Exact identifier

R1170531-0XUni-Strut beam — Serial-configured or incomplete reference.
Referenced part numberR1170531-0X
R05512613/8-16x 1.25in support mounting screw — Listed component.
Sources for this component

Description and scope

Exact identifier

R1170622-0Blower support bracket — Listed component.
Sources for this component

Description and scope

Exact identifier

R5550261-0Loop clamp — Listed component.
Sources for this component

Description and scope

Exact identifier

Selection boundaryOpening height greater than 16ft only. Blower requires factory identification; no number invented. Complete LH/RH assemblies and generic bracket-X stay configured. Exact bracket-1 is shown locally without inventing a bracket-2.
R1170706-1XLH RAD3 air-blower assembly — Serial-configured or incomplete reference.
Referenced part numberR1170706-1X
R1170706-2XRH RAD3 air-blower assembly — Serial-configured or incomplete reference.
Referenced part numberR1170706-2X
R1170625-1Air-blower bracket in exploded detail — Listed component.
Sources for this component

Description and scope

Exact identifier

R05502613/8-16x 1.25in flanged screw — Listed component.
Sources for this component

Description and scope

Exact identifier

R05533153/8-16 hex locknut — Listed component.
Sources for this component

Description and scope

Exact identifier

R1170625-XConfigured air-blower bracket — Serial-configured or incomplete reference.
Referenced part numberR1170625-X
Serial and revision scopeTurbo-Seal Insulated Gen 2 R1170741-0 revisionAA December 21 2017. Confirm matching installed serial numbers across System 4 control, side columns and head/motor assembly; use the individual door wiring schematic. Left/right are viewed from the front. Actual installed parts may differ from manual illustrations because of special engineering or revision. Preserve opening-height, drive-hand, motor and encoder arrangement conditions; X references require serial configuration. R and RS prefixes are literal identifiers, not automatic aliases to unprefixed numbers. Generic substitution language does not establish an exact successor.

Sources & review dates

  1. Rytec Powerhouse SD owner manual R1600157-0, April 12 2023Rytec · US · checked 2026-09-13 · R1600157-0 April 12 2023
  2. Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Rytec · US · checked 2026-09-13 · R1170931-0 RevA March 1 2020
  3. Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Rytec · US · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017

This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.

The cited sources define the product details shown here; comparison does not establish fitment.