Identification details & limits
Reference identifier: Turbo-Seal Insulated Gen2 blowers: selection above and below16ft. Compare each listed detail with the exact product and the source document. Do not submit a personal serial number or access code to this website.
- Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Turbo-Seal Insulated Gen2 R1170741-0 AA December21 2017, PDF page39, printed page31: Blowers and brackets for PH<=16ft · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R0014267 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R0021603 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R1170533-0 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R5550241-0Z01 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Powerhouse SD owner manual R1600157-0, April 12 2023Powerhouse SD R1600157-0, April 12 2023, PDF 43, printed 35: R0550261 · checked 2026-09-13 · R1600157-0 April 12 2023 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R0555146 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Turbo-Seal Insulated Gen2 R1170741-0 AA December21 2017, PDF page39, printed page31: R0551261 · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R1170622-0 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Sure-Seal R1170931-0 RevA, March 1 2020, PDF 33, printed 25: R5550261-0 · checked 2026-09-13 · R1170931-0 RevA March 1 2020 · Rytec
- Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Turbo-Seal Insulated Gen2 R1170741-0 AA December21 2017, PDF page40, printed page32: RAD3 blowers for PH>16ft · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017 · Rytec
- Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Turbo-Seal Insulated Gen2 R1170741-0 AA December21 2017, PDF page40, printed page32: R1170625-1 · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017 · Rytec
- Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Turbo-Seal Insulated Gen2 R1170741-0 AA December21 2017, PDF page40, printed page32: R0553315 · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017 · Rytec
| Selection boundary | Opening height at most 16ft only. Complete blower and Uni-Strut beam have X suffixes. R0550261 flange screw at blower andR0551261 support screw are distinct printed references; no numeric repair. Blower spacing depends on opening width.
|
|---|---|
| R1170530-0X | Black blower assembly — Serial-configured or incomplete reference.
|
| Referenced part number | R1170530-0X
|
| R0014267 | Blower power cord — Listed component.
|
| Exact component number | R0014267
|
| Exact-number source trace | R0014267
|
| R0021603 | 1/4-20x.375in flanged screw — Listed component.
|
| Exact component number | R0021603
|
| Exact-number source trace | R0021603
|
| R1170533-0 | Blower — Listed component.
|
| Exact component number | R1170533-0
|
| Exact-number source trace | R1170533-0
|
| R5550241-0Z01 | 3/8-16 Uni-Strut nut — Listed component.
|
| Exact component number | R5550241-0Z01
|
| Exact-number source trace | R5550241-0Z01
|
| R0550261 | 3/8-16x 1.25in flanged blower mounting screw — Listed component.
|
| Exact component number | R0550261
|
| Exact-number source trace | R0550261
|
| R0555146 | 3/8in flat washer — Listed component.
|
| Exact component number | R0555146
|
| Exact-number source trace | R0555146
|
| R1170531-0X | Uni-Strut beam — Serial-configured or incomplete reference.
|
| Referenced part number | R1170531-0X
|
| R0551261 | 3/8-16x 1.25in support mounting screw — Listed component.
|
| Exact component number | R0551261
|
| Exact-number source trace | R0551261
|
| R1170622-0 | Blower support bracket — Listed component.
|
| Exact component number | R1170622-0
|
| Exact-number source trace | R1170622-0
|
| R5550261-0 | Loop clamp — Listed component.
|
| Exact component number | R5550261-0
|
| Exact-number source trace | R5550261-0
|
| Selection boundary | Opening height greater than 16ft only. Blower requires factory identification; no number invented. Complete LH/RH assemblies and generic bracket-X stay configured. Exact bracket-1 is shown locally without inventing a bracket-2.
|
| R1170706-1X | LH RAD3 air-blower assembly — Serial-configured or incomplete reference.
|
| Referenced part number | R1170706-1X
|
| R1170706-2X | RH RAD3 air-blower assembly — Serial-configured or incomplete reference.
|
| Referenced part number | R1170706-2X
|
| R1170625-1 | Air-blower bracket in exploded detail — Listed component.
|
| Exact component number | R1170625-1
|
| Exact-number source trace | R1170625-1
|
| R0550261 | 3/8-16x 1.25in flanged screw — Listed component.
|
| Exact-number source trace | R0550261
|
| R0553315 | 3/8-16 hex locknut — Listed component.
|
| Exact component number | R0553315
|
| Exact-number source trace | R0553315
|
| R1170625-X | Configured air-blower bracket — Serial-configured or incomplete reference.
|
| Referenced part number | R1170625-X
|
| Serial and revision scope | Turbo-Seal Insulated Gen 2 R1170741-0 revisionAA December 21 2017. Confirm matching installed serial numbers across System 4 control, side columns and head/motor assembly; use the individual door wiring schematic. Left/right are viewed from the front. Actual installed parts may differ from manual illustrations because of special engineering or revision. Preserve opening-height, drive-hand, motor and encoder arrangement conditions; X references require serial configuration. R and RS prefixes are literal identifiers, not automatic aliases to unprefixed numbers. Generic substitution language does not establish an exact successor.
|
Sources & review dates
- Rytec Powerhouse SD owner manual R1600157-0, April 12 2023Rytec · US · checked 2026-09-13 · R1600157-0 April 12 2023
- Rytec Sure-Seal owner manual R1170931-0 RevA, March 1 2020Rytec · US · checked 2026-09-13 · R1170931-0 RevA March 1 2020
- Rytec Turbo-Seal Insulated Gen2 owner manual R1170741-0 AA December21 2017Rytec · US · checked 2026-09-13 · TSI Gen2 R1170741-0 AA December21 2017
This independent reference preserves the source’s stated scope. It does not report an Anderson installation inspection, product test or safety clearance.
The cited sources define the product details shown here; comparison does not establish fitment. Anderson’s repair service covers its listed Connecticut communities; this national reference does not imply nationwide service.