Miller Edge / Accessory reference
Miller Edge CPT223: double-T sensing-edge configuration and channel selection
CPT223: double-T sensing-edge configuration and channel selection
Match the whole number.
Manufacturer identifier: CPT223. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 1: Application · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Material and contact · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Ordering length · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Sensitivity · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Lead and outlet · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Electrical limit · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Monitored choices · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Non-monitored choice · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Cross-section · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Temperature boundary · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Listed mounting options · checked 2026-09-14 · CPT223_20220901 · Miller Edge
- CPT223 field-configurable sensing edgeCPT223_20220901, PDF page 2: Selection boundary · checked 2026-09-14 · CPT223_20220901 · Miller Edge
| Application | Field-configurable double-T edge for motorized doors and 2-inch mounting surfaces. Confirm the supplied edge and mounting geometry.
|
|---|---|
| Material and contact | Black flexible PVC exterior with conductive-polymer contact element.
|
| Ordering length | Finished edge: 1/4-inch ordering increments with +/-1/4-inch manufacturing tolerance. The 50-foot figure describes bulk extrusion; it is not a verified maximum finished monitored-edge length.
|
| Sensitivity | Nominal 7-12 lbf.
|
| Lead and outlet | 18-inch SJTO 22-gauge lead with universal end plug.
|
| Electrical limit | Maximum 24 V AC/DC, 1/2 amp; normally open.
|
| Monitored choices | 2-wire configurations with 6.8K, 8.2K, 10K or 270K resistor, .00001 MFD capacitor, or diode capacitor. The exact termination must match the control input.
|
| Non-monitored choice | 2-wire non-monitored is listed separately; it does not substitute for a required monitored configuration.
|
| Cross-section | Overall width 1-11/16 inches (42 mm), height 1-5/8 inches (41 mm). The upper dimension is 1-9/16 inches (39 mm); the local T dimension is 1/4 inch (7 mm).
|
| Temperature boundary | The source gives no numeric operating-temperature range. Confirm application requirements with Miller Edge.
|
| Listed mounting options | ME123-C, ME123-C1, ME123-C2175, ME123-C3 and ME123-C7 are high-density PVC; ME123-CA3 is brushed aluminum. Match the exact channel geometry before selection.
|
| Selection boundary | CPT223 does not establish a configured edge from its family number alone. Match length, channel, outlet, termination and operator requirements. No Air-Wave or Pneumatic option is listed in this sheet.
|
Documented fitment & exclusions
Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.
A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.
| Equipment or component / relationship | Evidence and conditions |
|---|---|
| ME123-C Documented compatibility From CPT223 to ME123-C. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT223 is named with ME123-C only within the reviewed source conditions. Applies only within this source scope
|
| ME123-C1 Documented compatibility From CPT223 to ME123-C1. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT223 is named with ME123-C1 only within the reviewed source conditions. Applies only within this source scope
|
| ME123-C2175 Documented compatibility From CPT223 to ME123-C2175. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT223 is named with ME123-C2175 only within the reviewed source conditions. Applies only within this source scope
|
| ME123-C3 Documented compatibility From CPT223 to ME123-C3. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT223 is named with ME123-C3 only within the reviewed source conditions. Applies only within this source scope
|
| ME123-C7 Documented compatibility From CPT223 to ME123-C7. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT223 is named with ME123-C7 only within the reviewed source conditions. Applies only within this source scope
|
| ME123-CA3 Documented compatibility From CPT223 to ME123-CA3. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT223 is named with ME123-CA3 only within the reviewed source conditions. Applies only within this source scope
|
Direct replacement paths
No direct successor for CPT223 is verified in this reference.
A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.
Compare exact equipment or a component.
Check a part or accessory pairing
Recall references
No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.
Sources & scope
- CPT223 field-configurable sensing edgeMiller Edge · US · checked 2026-09-14 · CPT223_20220901
Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.
This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.
A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.