Miller Edge / Accessory reference

Miller Edge EIM-101: Non-monitored CPT edge interface module

EIM-101: Non-monitored CPT edge interface module

Match the whole number.

Manufacturer identifier: EIM-101. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.

Values apply to the exact identifier and scope in the cited source.
Specified applicationPre-2010 commercial relay-logic operators with a 24 V control circuit, using non-monitored CPT or other high-resistance sensing edges. Exact operator approval remains necessary.
View source and citation details
Input and outputNon-monitored CPT sensing-edge input; non-monitored normally open dry-contact output.
View source and citation details
Power contextThe table names the photo-eye input as the power source and lists 200 mA continuous current, with 1.4 A for 0.25 seconds. Confirm the actual operator supply.
View source and citation details
Included enclosureJB-02-P-W junction box with strain-relief fittings; four wire nuts and four self-tapping stainless mounting screws are listed.
View source and citation details
HousingABS module with epoxy potting; polycarbonate junction box. The sheet lists NEMA 4 protection.
View source and citation details
Table limitationThe row headed relay rating contains NEMA 4, Class 2 device rather than a contact-current rating. No amperage rating is inferred from that row.
View source and citation details
Selection boundaryThe related-products list explicitly covers any non-monitored Miller Edge CPT sensing edge. This is an input relationship, not approval to substitute non-monitored operation where monitored protection is required.
View source and citation details

Documented fitment & exclusions

Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.

A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.

Source statements and their exact conditions. Read the documented direction and conditions for each pairing.
Equipment or component / relationshipEvidence and conditions
CPT210

Documented compatibility

From CPT210 to EIM-101.

Conditional

CPT210 is within the explicitly listed non-monitored Miller Edge CPT input group for EIM-101.

Applies only within this source scope
  • Market: US
  • configuration: 2-wire non-monitored
  • Confirm the legacy relay-logic operator, 24 V control-circuit context and actual edge input. Non-monitored output is not a substitute where monitored entrapment protection is required.
CPT215

Documented compatibility

From CPT215 to EIM-101.

Conditional

CPT215 is within the explicitly listed non-monitored Miller Edge CPT input group for EIM-101.

Applies only within this source scope
  • Market: US
  • configuration: 2-wire non-monitored
  • Confirm the legacy relay-logic operator, 24 V control-circuit context and actual edge input. Non-monitored output is not a substitute where monitored entrapment protection is required.
  • Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Exact non-monitored CPT profile option · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
  • Electrical Interface Module EIM-101EIM-101_V01, PDF page 2: Any non-monitored Miller Edge CPT group · checked 2026-09-14 · EIM-101_V01 · Miller Edge

Direct replacement paths

No direct successor for EIM-101 is verified in this reference.

A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.

The listed pairing applies in the direction shown above. Open the listed component’s reference to check its pairing with this item. You can also look up another part or accessory. A missing pairing does not establish incompatibility.

Recall references

No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.

Sources & scope

  1. Miller Edge CPT210 sensing edgeMiller Edge · US · checked 2026-09-13 · CPT210_spec_20251112
  2. Miller Edge CPT215 sensing edgeMiller Edge · US · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215)
  3. Electrical Interface Module EIM-101Miller Edge · US · checked 2026-09-14 · EIM-101_V01

Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.

This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status.

A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.