Miller Edge / Accessory reference
Miller Edge CPT215: Sensing-edge profile and configuration selection
CPT215: Sensing-edge profile and configuration selection
Match the whole number.
Manufacturer identifier: CPT215. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 1: Profile application · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 1: Mounting arrangement · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Profile width · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Profile height · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Materials · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Maximum electric-edge length · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Outlet selection · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Documented configuration choices · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Selection boundary · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
- Miller Edge CPT215 sensing edgeCPT210_Spec_20250917 (printed footer; both page headings identify CPT215), PDF page 2: Source limitation · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215) · Miller Edge
| Profile application | Commercial motorized doors with a two-inch surface application; separate gate and industrial uses are also listed.
|
|---|---|
| Mounting arrangement | Field-configurable double-T extrusion with separate end kits and six named mounting-channel options.
|
| Profile width | 1-11/16 inches
|
| Profile height | 1-5/8 inches
|
| Materials | Flexible PVC and conductive-polymer extrusion with molded-polymer ends. ME123-CA3 is brushed aluminum; the other channels are high-density PVC.
|
| Maximum electric-edge length | 50 feet
|
| Outlet selection | Universal end plug; the listed lead is 12 inches, 22 gauge.
|
| Documented configuration choices | 2-wire monitored 10K; 2-wire monitored 8.2K; 2-wire monitored diode capacitor; 2-wire non-monitored
|
| Selection boundary | A profile name does not specify the complete configured edge. Confirm the required length, mounting geometry, outlet, monitored or non-monitored switch configuration, termination and exact operator requirements with Miller Edge. This reference does not establish fitment for every door or opener.
|
| Source limitation | Both page headings, the application description and end-kit labels identify CPT215, but the footer prints CPT210_Spec_20250917. Retain that document-label discrepancy; it is not a product alias.
|
| Source limitation | The sheet lists two-wire monitored and non-monitored options, not a four-wire monitored version. No cross-profile end-kit interchangeability is established.
|
Documented fitment & exclusions
Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.
A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.
| Equipment or component / relationship | Evidence and conditions |
|---|---|
| EIM-101 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT215 is within the explicitly listed non-monitored Miller Edge CPT input group for EIM-101. Applies only within this source scope
|
| FSIS-35P-4 Documented compatibility From CPT215 to FSIS-35P-4. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT215 is in the explicitly named Miller Edge 2/4-wire sensing-edge input group for FSIS-35P-4. Applies only within this source scope
|
| MEL-K20 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT215 falls within the MEL-K20 sheet's explicit T2 (10K) monitored sensing-edge group only with the matching configured termination. Applies only within this source scope
|
| SM-101 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT215 is within the documented Miller Edge sensing-edge group for SM-101 only when configured with the matching two-wire monitored termination. Applies only within this source scope
|
| SM-102 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. CPT215 is within the documented Miller Edge sensing-edge group for SM-102 only when configured with the matching two-wire monitored termination. Applies only within this source scope
|
| LED-ARIES-ME123C-K10 Documented compatibility From LED-ARIES-ME123C-K10 to CPT215. | LED-ARIES-ME123C-K10 explicitly accepts CPT215 in its integrated leading-edge channel. Applies only within this source scope
|
| LED-ARIES-ME123C-K12 Documented compatibility From LED-ARIES-ME123C-K12 to CPT215. | LED-ARIES-ME123C-K12 explicitly accepts CPT215 in its integrated leading-edge channel. Applies only within this source scope
|
| LED-ARIES-ME123C-K14 Documented compatibility From LED-ARIES-ME123C-K14 to CPT215. | LED-ARIES-ME123C-K14 explicitly accepts CPT215 in its integrated leading-edge channel. Applies only within this source scope
|
| LED-ARIES-ME123C-K8 Documented compatibility From LED-ARIES-ME123C-K8 to CPT215. | LED-ARIES-ME123C-K8 explicitly accepts CPT215 in its integrated leading-edge channel. Applies only within this source scope
|
| ME123-C Documented compatibility From ME123-C to CPT215. | ME123-C is a source-listed mounting channel for CPT215; mechanical selection only. Applies only within this source scope
|
| ME123-C1 Documented compatibility From ME123-C1 to CPT215. | ME123-C1 is a source-listed mounting channel for CPT215; mechanical selection only. Applies only within this source scope
|
| ME123-C2175 Documented compatibility From ME123-C2175 to CPT215. | ME123-C2175 is a source-listed mounting channel for CPT215; mechanical selection only. Applies only within this source scope
|
| ME123-C3 Documented compatibility From ME123-C3 to CPT215. | ME123-C3 is a source-listed mounting channel for CPT215; mechanical selection only. Applies only within this source scope
|
| ME123-C7 Documented compatibility From ME123-C7 to CPT215. | ME123-C7 is a source-listed mounting channel for CPT215; mechanical selection only. Applies only within this source scope
|
| ME123-CA3 Documented compatibility From ME123-CA3 to CPT215. | ME123-CA3 is a source-listed mounting channel for CPT215; mechanical selection only. Applies only within this source scope
|
Direct replacement paths
No direct successor for CPT215 is verified in this reference.
A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.
Compare exact equipment or a component.
Check a part or accessory pairing
Recall references
No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.
Sources & scope
- Aries LED-ARIES visual alert systemMiller Edge · US · checked 2026-09-14 · LED-ARIES_Spec_20260521
- Miller Edge CPT215 sensing edgeMiller Edge · US · checked 2026-09-13 · CPT210_Spec_20250917 (printed footer; both page headings identify CPT215)
- Electrical Interface Module EIM-101Miller Edge · US · checked 2026-09-14 · EIM-101_V01
- FSIS-35P-4 intrinsically safe relay controllerMiller Edge · US · checked 2026-09-14 · FSIS-35P-4_20211111
- Monitored Edge Link MEL-K20Miller Edge · US · checked 2026-09-14 · MEL-K20_Spec_20150303
- Signature Module SM-101 and SM-102Miller Edge · US · checked 2026-09-13 · SM101-SM102_20230407
Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.
This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.
A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.
