Miller Edge / Accessory reference
Miller Edge AW10: Bare air-wave switch
AW10: Bare air-wave switch
Match the whole number.
Manufacturer identifier: AW10. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 1: Edge scope · checked 2026-09-14 · AW101214_20210223 · Miller Edge
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 1: Monitoring · checked 2026-09-14 · AW101214_20210223 · Miller Edge
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 2: Housing · checked 2026-09-14 · AW101214_20210223 · Miller Edge
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 2: Switch limits · checked 2026-09-14 · AW101214_20210223 · Miller Edge
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 2: Electrical · checked 2026-09-14 · AW101214_20210223 · Miller Edge
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 2: Temperature · checked 2026-09-14 · AW101214_20210223 · Miller Edge
- AW10, AW12A and AW14 wired air-wave switchesAW101214_20210223, PDF page 1: Selection boundary · checked 2026-09-14 · AW101214_20210223 · Miller Edge
| Edge scope | Miller Edge Air-Wave configured sensing edges up to 60 feet. The actual edge profile may have a shorter limit.
|
|---|---|
| Monitoring | Non-monitored air-wave pressure switch.
|
| Housing | ABS switch only;1-3/4 W x1-1/4 H x1-1/4 D inches (44 x32 x32 mm). No enclosure-protection rating listed.
|
| Switch limits | Maximum pressure 3 PSI; maximum switching frequency 25 per second; adjustable sensitivity0.078-19.7 inches (2-500 mm) water column.
|
| Electrical | Contact output row lists N.O. and N.C.; electrical-configuration row specifies2-wire N.O. Maximum contact load 0.5 A at 220 V AC or 1 A at 48 V DC;0.187-inch quick-connect tabs.
|
| Temperature | -49 to +180 degrees F (-45 to +82 degrees C).
|
| Selection boundary | Confirm the exact door, edge configuration and installed control requirements with the manufacturer. A non-monitored component does not replace monitoring required by the installed system.
|
Documented fitment & exclusions
Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.
A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.
| Equipment or component / relationship | Evidence and conditions |
|---|---|
| MC22 Documented compatibility | MC22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME110 Documented compatibility | ME110 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME111 Documented compatibility | ME111 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME113 Documented compatibility | ME113 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME116 Documented compatibility | ME116 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME117 Documented compatibility | ME117 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME120 Documented compatibility | ME120 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME123 Documented compatibility | ME123 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| ME190 Documented compatibility | ME190 is named with AW10 only within the reviewed source conditions. Applies only within this source scope
|
| MT21 Documented compatibility | MT21 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| MT22 Documented compatibility | MT22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| MT33 Documented compatibility | MT33 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| MU21 Documented compatibility | MU21 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| MU22 Documented compatibility | MU22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
| MU33 Documented compatibility | MU33 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10. Applies only within this source scope
|
Direct replacement paths
No direct successor for AW10 is verified in this reference.
A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.
Compare exact equipment or a component.
Check a part or accessory pairing
Recall references
No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.
Sources & scope
- AW10, AW12A and AW14 wired air-wave switchesMiller Edge · US · checked 2026-09-14 · AW101214_20210223
- Miller Edge MC22 sensing edgeMiller Edge · US · checked 2026-09-13 · MC22_spec_20260506
- Miller Edge ME110 sensing edgeMiller Edge · US · checked 2026-09-13 · ME110_V7
- Miller Edge ME111 sensing edgeMiller Edge · US · checked 2026-09-13 · ME111_20201218
- Miller Edge ME113 sensing edgeMiller Edge · US · checked 2026-09-13 · ME113_20201218
- Miller Edge ME116 sensing edgeMiller Edge · US · checked 2026-09-13 · ME116_20201218
- Miller Edge ME117 sensing edgeMiller Edge · US · checked 2026-09-13 · ME117_20201218
- Miller Edge ME120 sensing edgeMiller Edge · US · checked 2026-09-13 · ME120_20201218
- Miller Edge ME123 sensing edgeMiller Edge · US · checked 2026-09-13 · ME123_20201218
- ME190 vehicle treadleMiller Edge · US · checked 2026-09-14 · ME190_20250617
- Miller Edge MT21 sensing edgeMiller Edge · US · checked 2026-09-13 · MT_20201218
- Miller Edge MU21 sensing edgeMiller Edge · US · checked 2026-09-13 · MU21_20220607
- Miller Edge MU22 sensing edgeMiller Edge · US · checked 2026-09-13 · MU22_20220607
- Miller Edge MU33 sensing edgeMiller Edge · US · checked 2026-09-13 · MU33_20220512
Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.
This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.
A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.