Edge scopeMiller Edge Air-Wave configured sensing edges up to 60 feet. The actual edge profile may have a shorter limit.
MonitoringNon-monitored air-wave pressure switch.
HousingAW10 in a NEMA1 ABS enclosure;1-15/16 W x3-3/8 H x1-11/16 D inches (50 x85 x43 mm).
Switch limitsMaximum pressure 3 PSI; maximum switching frequency 25 per second; adjustable sensitivity0.078-19.7 inches (2-500 mm) water column.
ElectricalContact output row lists N.O. and N.C.; electrical-configuration row specifies2-wire N.O. Maximum contact load 0.5 A at 220 V AC or 1 A at 48 V DC;0.187-inch quick-connect tabs.
Temperature-49 to +180 degrees F (-45 to +82 degrees C).
Selection boundaryConfirm the exact door, edge configuration and installed control requirements with the manufacturer. A non-monitored component does not replace monitoring required by the installed system.

Documented fitment & exclusions

Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.

A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.

Source statements and their exact conditions. Use the checker below to compare equipment or a component.
Equipment or component / relationshipEvidence and conditions
MC22

Documented compatibility

From MC22 to AW14.

MC22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME110

Documented compatibility

From ME110 to AW14.

ME110 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME111

Documented compatibility

From ME111 to AW14.

ME111 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME113

Documented compatibility

From ME113 to AW14.

ME113 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME116

Documented compatibility

From ME116 to AW14.

ME116 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME117

Documented compatibility

From ME117 to AW14.

ME117 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME120

Documented compatibility

From ME120 to AW14.

ME120 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME123

Documented compatibility

From ME123 to AW14.

ME123 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
ME190

Documented compatibility

From ME190 to AW14.

ME190 is named with AW14 only within the reviewed source conditions.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave
  • Use only the ME190 Air-Wave configuration, matching lead hose and external switch; maximum treadle length10 feet.
  • This is non-monitored vehicle activation. Confirm the installed control input and application with Miller Edge; it is not entrapment protection or a wireless-system approval.
  • ME190 vehicle treadleME190_20250617, PDF page 2: Explicit named component scope · checked 2026-09-14 · ME190_20250617 · Miller Edge
MT21

Documented compatibility

From MT21 to AW14.

MT21 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
MT22

Documented compatibility

From MT22 to AW14.

MT22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
MT33

Documented compatibility

From MT33 to AW14.

MT33 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
MU21

Documented compatibility

From MU21 to AW14.

MU21 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
MU22

Documented compatibility

From MU22 to AW14.

MU22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
MU33

Documented compatibility

From MU33 to AW14.

MU33 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.

Direct replacement paths

No direct successor for AW14 is verified in this reference.

A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.

Compare exact equipment or a component.

Check a part or accessory pairing

Loading part or accessory choices…

Selected: AW14 · Read its reference. Selection identifies a record; it does not confirm fitment.

Choose the equipment or accessory brand separately from the component brand. A missing identifier is unverified. Use the model library to identify your equipment and its source documents.

An accessory pairing, including a receiver or wall console, applies only to the exact listed pair and source conditions. It does not establish suitability for your installed opener or compatibility through another device.

Choose the equipment or accessory brand to load its published identifiers.

Use the production date on the label or records, not the purchase date. Leave blank if unknown.

Use part and model numbers only. Never enter a serial number, PIN or access code. Your entry is used for this lookup and is not put in the page address, saved in browser storage or sent to analytics.

Choose a task and enter or select an exact identifier.

Recall references

No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.

Sources & scope

  1. AW10, AW12A and AW14 wired air-wave switchesMiller Edge · US · checked 2026-09-14 · AW101214_20210223
  2. Miller Edge MC22 sensing edgeMiller Edge · US · checked 2026-09-13 · MC22_spec_20260506
  3. Miller Edge ME110 sensing edgeMiller Edge · US · checked 2026-09-13 · ME110_V7
  4. Miller Edge ME111 sensing edgeMiller Edge · US · checked 2026-09-13 · ME111_20201218
  5. Miller Edge ME113 sensing edgeMiller Edge · US · checked 2026-09-13 · ME113_20201218
  6. Miller Edge ME116 sensing edgeMiller Edge · US · checked 2026-09-13 · ME116_20201218
  7. Miller Edge ME117 sensing edgeMiller Edge · US · checked 2026-09-13 · ME117_20201218
  8. Miller Edge ME120 sensing edgeMiller Edge · US · checked 2026-09-13 · ME120_20201218
  9. Miller Edge ME123 sensing edgeMiller Edge · US · checked 2026-09-13 · ME123_20201218
  10. ME190 vehicle treadleMiller Edge · US · checked 2026-09-14 · ME190_20250617
  11. Miller Edge MT21 sensing edgeMiller Edge · US · checked 2026-09-13 · MT_20201218
  12. Miller Edge MU21 sensing edgeMiller Edge · US · checked 2026-09-13 · MU21_20220607
  13. Miller Edge MU22 sensing edgeMiller Edge · US · checked 2026-09-13 · MU22_20220607
  14. Miller Edge MU33 sensing edgeMiller Edge · US · checked 2026-09-13 · MU33_20220512

Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.

This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.

A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.

Call (203) 902-3902 — Check Today's Availability