Miller Edge / Accessory reference

Miller Edge MC22: Sensing-edge profile and configuration selection

MC22: Sensing-edge profile and configuration selection

Match the whole number.

Manufacturer identifier: MC22. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.

Values apply to the exact identifier and scope in the cited source.
Profile applicationCommercial sectional and rolling doors and rolling grilles, with a suitable accepting bottom retainer.
Mounting arrangementExtruded T on a reinforced flexible edge. The two reviewed sources name different channels for a two-inch double-angle bottom bar.
Profile width2-inch body; 3-1/4-inch overall top width in the May 2026 drawing
Profile height2-1/4 inches in the May 2026 drawing
MaterialsHeavy-duty reinforced PVC.
Maximum electric-edge length150 feet
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Maximum electric-edge length · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
Outlet selectionLeft, right or universal.
Documented configuration choices2-wire monitored 10K; 2-wire monitored 8.2K; 2-wire monitored diode capacitor; 4-wire monitored; 2-wire non-monitored; Air-Wave non-monitored; Pneumatic non-monitored
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Documented configuration choices · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
Selection boundaryA profile name does not specify the complete configured edge. Confirm the required length, mounting geometry, outlet, monitored or non-monitored switch configuration, termination and exact operator requirements with Miller Edge. This reference does not establish fitment for every door or opener.
Source limitationThe February 2026 brochure names MC22-C7 and gives a 2 x 2 inch profile; the May 2026 sheet names MC271-C7 and shows a 2-inch body with a 2-1/4-inch height. These may reflect a changed product or a source error; the sources do not establish which. No alias, replacement or definite channel-selection edge is approved.
Source limitationConfirm the current supplied profile, bottom-bar arrangement and exact channel with Miller Edge.
Brochure comparisonThe February 2026 brochure lists MC22-C7 and a 2 x 2 inch profile. The May 2026 sheet differs; confirm the current supplied configuration.

Documented fitment & exclusions

Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.

A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.

Source statements and their exact conditions. Use the checker below to compare equipment or a component.
Equipment or component / relationshipEvidence and conditions
AW10

Documented compatibility

From MC22 to AW10.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW10.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
AW12A

Documented compatibility

From MC22 to AW12A.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW12A.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
AW14

Documented compatibility

From MC22 to AW14.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The wired switch group supports edges up to 60 feet, but a lower limit printed for the exact edge profile takes precedence. Confirm the switch contact and circuit configuration.
AW14-RF

Documented compatibility

From MC22 to AW14-RF.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 has an explicitly listed Air-Wave non-monitored option within the source-defined input group for AW14-RF.

Applies only within this source scope
  • Market: US
  • configuration: Air-Wave non-monitored
  • Match the exact Air-Wave non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • The radio distance is not an edge-length rating. Use the exact AW14-RF and MRF-01 system, confirm the profile length and resolve the documented receiver supply conflict.
FSC-57-115VAC

Documented compatibility

From MC22 to FSC-57-115VAC.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. This exact model specifies115 V AC.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
FSC-57-24VDC

Documented compatibility

From MC22 to FSC-57-24VDC.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
FSIS-35P-4

Documented compatibility

From MC22 to FSIS-35P-4.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is in the explicitly named Miller Edge 2/4-wire sensing-edge input group for FSIS-35P-4.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm exact input configuration and the full circuit with the responsible qualified designer. The group statement does not approve the edge for a classified location, establish intrinsic safety of the installation, or certify a complete door safety function.
MC22-C7

Documented compatibility

From MC22 to MC22-C7.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is named with MC22-C7 only within the reviewed source conditions.

Applies only within this source scope
  • Market: US
  • configuration: December 2025 instruction: 2-inch double-angle bottom bars
  • Mechanical scope is restricted to the MC22 edge and rolling-steel-door arrangement described in the December 2025 instructions.
  • The newer May 2026 MC22 sheet names MC271-C7 and differs in profile dimensions. This conflict remains unresolved; confirm actual profile, bottom bar and exact channel with Miller Edge before selection.
  • MC22-C7-K46 versus MC22-C7-K5 is an unresolved instruction-header conflict. No alias, replacement, kit equivalence or definite present-day fitment is established.
MEL-K20

Documented compatibility

From MC22 to MEL-K20.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • termination
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 falls within the MEL-K20 sheet's explicit T2 (10K) monitored sensing-edge group only with the matching configured termination.

Applies only within this source scope
  • Market: US
  • configuration: 2-wire monitored
  • termination: 10K resistive
  • The source qualifies monitored operation with its UL325-2010 listed commercial door/gate operator context. The specific installed operator still requires confirmation; this group relationship is only the sensing-edge input scope.
  • This does not establish MEL-II or RBand compatibility, present product availability, or an installed-operator approval.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact profile monitored 10K membership · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • Monitored Edge Link MEL-K20MEL-K20_Spec_20150303, PDF page 1: Any T2 (10K) monitored edge group and listed-operator condition · checked 2026-09-14 · MEL-K20_Spec_20150303 · Miller Edge
PS20A

Documented compatibility

From MC22 to PS20A.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 has an explicitly listed Pneumatic non-monitored option within the source-defined input group for PS20A.

Applies only within this source scope
  • Market: US
  • configuration: Pneumatic non-monitored
  • Match the exact Pneumatic non-monitored profile option and its own length limit; the electric-profile length is not the pneumatic or air-wave length. Confirm the installed control and required monitoring with the manufacturer. This is a conditional component-input relationship, not whole-door approval.
  • PS20A supports pneumatic configured edges up to 18 feet; any lower profile-specific limit also applies. Match the required contact configuration.
RT6-115VAC

Documented compatibility

From MC22 to RT6-115VAC.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is within the exact four-wire Miller Edge input group listed for RT6-115VAC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. This exact model specifies115 V AC.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
RT6-24VDC

Documented compatibility

From MC22 to RT6-24VDC.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is within the exact four-wire Miller Edge input group listed for RT6-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
SM-101

Documented compatibility

From MC22 to SM-101.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • termination
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is within the documented Miller Edge sensing-edge group for SM-101 only when configured with the matching two-wire monitored termination.

Applies only within this source scope
  • Market: US
  • configuration: 2-wire monitored
  • termination: Diode capacitor
  • Confirm the exact supplied termination and the installed commercial door operator requirements with Miller Edge. This is an edge-to-module input relationship, not approval of the downstream operator or a complete safety system.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact profile monitored configuration membership · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • Signature Module SM-101 and SM-102SM101-SM102_20230407, PDF page 2: Related-products group scope and model-specific input table · checked 2026-09-13 · SM101-SM102_20230407 · Miller Edge
SM-102

Documented compatibility

From MC22 to SM-102.

Conditional

Additional source conditions or an adapter must be checked before confirming compatibility.

Details still needed
  • configuration
  • termination
  • source conditions

Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified.

MC22 is within the documented Miller Edge sensing-edge group for SM-102 only when configured with the matching two-wire monitored termination.

Applies only within this source scope
  • Market: US
  • configuration: 2-wire monitored
  • termination: 10K resistive
  • Confirm the exact supplied termination and the installed commercial door operator requirements with Miller Edge. This is an edge-to-module input relationship, not approval of the downstream operator or a complete safety system.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact profile monitored configuration membership · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • Signature Module SM-101 and SM-102SM101-SM102_20230407, PDF page 2: Related-products group scope and model-specific input table · checked 2026-09-13 · SM101-SM102_20230407 · Miller Edge

Direct replacement paths

No direct successor for MC22 is verified in this reference.

A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.

Compare exact equipment or a component.

Check a part or accessory pairing

Loading part or accessory choices…

Selected: MC22 · Read its reference. Selection identifies a record; it does not confirm fitment.

Choose the equipment or accessory brand separately from the component brand. A missing identifier is unverified. Use the model library to identify your equipment and its source documents.

An accessory pairing, including a receiver or wall console, applies only to the exact listed pair and source conditions. It does not establish suitability for your installed opener or compatibility through another device.

Choose the equipment or accessory brand to load its published identifiers.

Use the production date on the label or records, not the purchase date. Leave blank if unknown.

Use part and model numbers only. Never enter a serial number, PIN or access code. Your entry is used for this lookup and is not put in the page address, saved in browser storage or sent to analytics.

Choose a task and enter or select an exact identifier.

Recall references

No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.

Sources & scope

  1. AW10, AW12A and AW14 wired air-wave switchesMiller Edge · US · checked 2026-09-14 · AW101214_20210223
  2. AW14-RF-K10 wireless air-wave edge systemMiller Edge · US · checked 2026-09-14 · AW14RF_20210101
  3. Miller Edge Door Safety brochureMiller Edge · US · checked 2026-09-13 · 202602
  4. FSIS-35P-4 intrinsically safe relay controllerMiller Edge · US · checked 2026-09-14 · FSIS-35P-4_20211111
  5. Miller Edge MC22 sensing edgeMiller Edge · US · checked 2026-09-13 · MC22_spec_20260506
  6. MC22-C7 mounting channel instructionsMiller Edge · US · checked 2026-09-14 · MC22-C7_inst_20251203
  7. Monitored Edge Link MEL-K20Miller Edge · US · checked 2026-09-14 · MEL-K20_Spec_20150303
  8. PS20A pneumatic switch and wired kit selectionMiller Edge · US · checked 2026-09-14 · PS20A_20210101
  9. PS20A and PS20-RF pneumatic systems and exact kit optionsMiller Edge · US · checked 2026-09-14 · PS20A20RF_Spec_20141208
  10. RT6 and FSC-57 safety relay controllersMiller Edge · US · checked 2026-09-14 · RT6_FSC-57_20211111
  11. Signature Module SM-101 and SM-102Miller Edge · US · checked 2026-09-13 · SM101-SM102_20230407

Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.

This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.

A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.

Call (203) 902-3902 — Check Today's Availability