Miller Edge FSC-57-24VDC: Enclosed sensing-edge relay controller

FSC-57-24VDC: Enclosed sensing-edge relay controller

Match the whole number.

Manufacturer identifier: FSC-57-24VDC. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.

Values apply to the exact identifier and scope in the cited source.
Exact model and packageFSC-57 packages the RT6 controller in a steel NEMA 13 enclosure with two LEDs and a reset button. Preserve the supply suffix.
Power identificationThe model name and first-page feature list specify 24 V DC, while the power table says 24 V AC/DC. AC acceptance is unresolved; confirm the exact unit's supply requirements.
Edge input groupThe related-products list explicitly names any model of 4-wire Miller Edge sensing edge. The controller table lists single- or dual-channel inputs.
Output identificationThree normally open outputs and one normally closed output. Exact load and reset configuration require the specific controller documentation.
Mounting and protectionExternal screw-mounting tabs and a steel NEMA 13 enclosure; the controller and terminal blocks retain separate IP40 and IP20 ratings.
Source limitationsThe enclosed model's height/depth figures in inches and millimeters disagree; confirm physical clearance. The temperature row pairs 133 F with 55 C, which are inconsistent. No corrected upper limit is inferred.
Selection boundaryConfirm the exact four-wire edge configuration, supply, required reset behavior and complete safety circuit with a qualified designer. The group match is not an installed-door or current certification approval.

Documented fitment & exclusions

Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.

A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.

Source statements and their exact conditions. Use the checker below to compare equipment or a component.
Equipment or component / relationshipEvidence and conditions
Clima-GUARD

Documented compatibility

From Clima-GUARD to FSC-57-24VDC.

Clima-GUARD is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
MC22

Documented compatibility

From MC22 to FSC-57-24VDC.

MC22 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
  • Miller Edge MC22 sensing edgeMC22_spec_20260506, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MC22_spec_20260506 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
ME110

Documented compatibility

From ME110 to FSC-57-24VDC.

ME110 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME111

Documented compatibility

From ME111 to FSC-57-24VDC.

ME111 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME112

Documented compatibility

From ME112 to FSC-57-24VDC.

ME112 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME113

Documented compatibility

From ME113 to FSC-57-24VDC.

ME113 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME116

Documented compatibility

From ME116 to FSC-57-24VDC.

ME116 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME117

Documented compatibility

From ME117 to FSC-57-24VDC.

ME117 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME120

Documented compatibility

From ME120 to FSC-57-24VDC.

ME120 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
ME123

Documented compatibility

From ME123 to FSC-57-24VDC.

ME123 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
MT21

Documented compatibility

From MT21 to FSC-57-24VDC.

MT21 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
MT22

Documented compatibility

From MT22 to FSC-57-24VDC.

MT22 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
MT33

Documented compatibility

From MT33 to FSC-57-24VDC.

MT33 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
MU21

Documented compatibility

From MU21 to FSC-57-24VDC.

MU21 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
  • Miller Edge MU21 sensing edgeMU21_20220607, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MU21_20220607 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
MU22

Documented compatibility

From MU22 to FSC-57-24VDC.

MU22 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
  • Miller Edge MU22 sensing edgeMU22_20220607, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MU22_20220607 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
MU33

Documented compatibility

From MU33 to FSC-57-24VDC.

MU33 is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC.

Applies only within this source scope
  • Market: US
  • configuration: 4-wire monitored
  • Confirm the controller supply, edge circuit, reset requirements and installed door safety function with a qualified designer. This is component-input scope only. The VDC model and first-page list say24 V DC; the table also saysAC. AC acceptance is unresolved.
  • Miller Edge MU33 sensing edgeMU33_20220512, PDF page 2: Exact four-wire monitored profile option · checked 2026-09-13 · MU33_20220512 · Miller Edge
  • RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Any model 4-wire Miller Edge sensing edge and model columns · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
RT6-24VDC

Documented compatibility

From RT6-24VDC to FSC-57-24VDC.

The matching-voltage FSC-57 package is explicitly described as an RT6 inside its enclosure.

Applies only within this source scope
  • Market: US
  • configuration: 24 V DC model identity
  • Confirm the exact supplied configuration and the installed operator requirements. This component relationship is limited to the documented package, input or mechanical role; it does not approve a complete door safety system.

Direct replacement paths

No direct successor for FSC-57-24VDC is verified in this reference.

A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.

Compare exact equipment or a component.

Check a part or accessory pairing

Loading part or accessory choices…

Selected: FSC-57-24VDC · Read its reference. Selection identifies a record; it does not confirm fitment.

Choose the equipment or accessory brand separately from the component brand. A missing identifier is unverified. Use the model library to identify your equipment and its source documents.

An accessory pairing, including a receiver or wall console, applies only to the exact listed pair and source conditions. It does not establish suitability for your installed opener or compatibility through another device.

Choose the equipment or accessory brand to load its published identifiers.

Use the production date on the label or records, not the purchase date. Leave blank if unknown.

Use part and model numbers only. Never enter a serial number, PIN or access code. Your entry is used for this lookup and is not put in the page address, saved in browser storage or sent to analytics.

Choose a task and enter or select an exact identifier.

Recall references

No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.

Sources & scope

  1. Miller Edge Clima-GUARD sensing edgeMiller Edge · US · checked 2026-09-13 · CLIMAGUARD_20220307
  2. Miller Edge MC22 sensing edgeMiller Edge · US · checked 2026-09-13 · MC22_spec_20260506
  3. Miller Edge ME110 sensing edgeMiller Edge · US · checked 2026-09-13 · ME110_V7
  4. Miller Edge ME111 sensing edgeMiller Edge · US · checked 2026-09-13 · ME111_20201218
  5. Miller Edge ME112 sensing edgeMiller Edge · US · checked 2026-09-13 · ME112_20201218
  6. Miller Edge ME113 sensing edgeMiller Edge · US · checked 2026-09-13 · ME113_20201218
  7. Miller Edge ME116 sensing edgeMiller Edge · US · checked 2026-09-13 · ME116_20201218
  8. Miller Edge ME117 sensing edgeMiller Edge · US · checked 2026-09-13 · ME117_20201218
  9. Miller Edge ME120 sensing edgeMiller Edge · US · checked 2026-09-13 · ME120_20201218
  10. Miller Edge ME123 sensing edgeMiller Edge · US · checked 2026-09-13 · ME123_20201218
  11. Miller Edge MT21 sensing edgeMiller Edge · US · checked 2026-09-13 · MT_20201218
  12. Miller Edge MU21 sensing edgeMiller Edge · US · checked 2026-09-13 · MU21_20220607
  13. Miller Edge MU22 sensing edgeMiller Edge · US · checked 2026-09-13 · MU22_20220607
  14. Miller Edge MU33 sensing edgeMiller Edge · US · checked 2026-09-13 · MU33_20220512
  15. RT6 and FSC-57 safety relay controllersMiller Edge · US · checked 2026-09-14 · RT6_FSC-57_20211111

Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.

This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.

A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.

Call (203) 902-3902 — Check Today's Availability