Miller Edge Clima-GUARD: Sensing-edge profile and configuration selection
Clima-GUARD: Sensing-edge profile and configuration selection
Match the whole number.
Manufacturer identifier: Clima-GUARD. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 1: Profile application · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 1: Mounting arrangement · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Profile width · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Profile height · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Materials · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Maximum electric-edge length · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Outlet selection · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Documented configuration choices · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Selection boundary · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
- Miller Edge Clima-GUARD sensing edgeCLIMAGUARD_20220307, PDF page 2: Source limitation · checked 2026-09-13 · CLIMAGUARD_20220307 · Miller Edge
| Profile application | Commercial sectional doors and some high-performance door arrangements; exact installed type remains necessary.
|
|---|---|
| Mounting arrangement | ME112 sensing edge combined with an LS-0107 loop seal and a double-slot channel.
|
| Profile width | 2-1/4 inches at the illustrated assembly
|
| Profile height | Approximately 3 inches overall in the illustrated assembly
|
| Materials | Flexible PVC edge and seal; high-density PVC mounting channels.
|
| Maximum electric-edge length | 100 feet
|
| Outlet selection | Left, right, end or top.
|
| Documented configuration choices | 2-wire monitored 10K; 2-wire monitored 8.2K; 2-wire monitored diode capacitor; 4-wire monitored; 2-wire non-monitored
|
| Selection boundary | A profile name does not specify the complete configured edge. Confirm the required length, mounting geometry, outlet, monitored or non-monitored switch configuration, termination and exact operator requirements with Miller Edge. This reference does not establish fitment for every door or opener.
|
| Source limitation | Clima-GUARD is a described assembly, not an alias for the ME112 component inside it. LS-0107 is the separately labelled loop seal.
|
| Source limitation | The maximum-length row mentions Air-Wave, but the options list only explicitly identifies electric configurations. No unqualified Air-Wave configuration is approved.
|
Documented fitment & exclusions
Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.
A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.
| Equipment or component / relationship | Evidence and conditions |
|---|---|
| FSC-57-115VAC Documented compatibility From Clima-GUARD to FSC-57-115VAC. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| FSC-57-24VDC Documented compatibility From Clima-GUARD to FSC-57-24VDC. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is within the exact four-wire Miller Edge input group listed for FSC-57-24VDC. Applies only within this source scope
|
| FSIS-35P-4 Documented compatibility From Clima-GUARD to FSIS-35P-4. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is in the explicitly named Miller Edge 2/4-wire sensing-edge input group for FSIS-35P-4. Applies only within this source scope
|
| MEL-K20 Documented compatibility From Clima-GUARD to MEL-K20. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD falls within the MEL-K20 sheet's explicit T2 (10K) monitored sensing-edge group only with the matching configured termination. Applies only within this source scope
|
| RT6-115VAC Documented compatibility From Clima-GUARD to RT6-115VAC. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is within the exact four-wire Miller Edge input group listed for RT6-115VAC. Applies only within this source scope
|
| RT6-24VDC Documented compatibility From Clima-GUARD to RT6-24VDC. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is within the exact four-wire Miller Edge input group listed for RT6-24VDC. Applies only within this source scope
|
| SM-101 Documented compatibility From Clima-GUARD to SM-101. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is within the documented Miller Edge sensing-edge group for SM-101 only when configured with the matching two-wire monitored termination. Applies only within this source scope
|
| SM-102 Documented compatibility From Clima-GUARD to SM-102. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. Clima-GUARD is within the documented Miller Edge sensing-edge group for SM-102 only when configured with the matching two-wire monitored termination. Applies only within this source scope
|
| ME112-C4 Documented compatibility From ME112-C4 to Clima-GUARD. | ME112-C4 is a source-listed mounting channel for Clima-GUARD; mechanical selection only. Applies only within this source scope
|
| ME112-C43 Documented compatibility From ME112-C43 to Clima-GUARD. | ME112-C43 is a source-listed mounting channel for Clima-GUARD; mechanical selection only. Applies only within this source scope
|
| ME112-C47 Documented compatibility From ME112-C47 to Clima-GUARD. | ME112-C47 is a source-listed mounting channel for Clima-GUARD; mechanical selection only. Applies only within this source scope
|
Direct replacement paths
No direct successor for Clima-GUARD is verified in this reference.
A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.
Compare exact equipment or a component.
Check a part or accessory pairing
Recall references
No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.
Sources & scope
- Miller Edge Clima-GUARD sensing edgeMiller Edge · US · checked 2026-09-13 · CLIMAGUARD_20220307
- FSIS-35P-4 intrinsically safe relay controllerMiller Edge · US · checked 2026-09-14 · FSIS-35P-4_20211111
- Monitored Edge Link MEL-K20Miller Edge · US · checked 2026-09-14 · MEL-K20_Spec_20150303
- RT6 and FSC-57 safety relay controllersMiller Edge · US · checked 2026-09-14 · RT6_FSC-57_20211111
- Signature Module SM-101 and SM-102Miller Edge · US · checked 2026-09-13 · SM101-SM102_20230407
Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.
This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.
A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.