Miller Edge / Accessory reference
Miller Edge FSC-57-115VAC: Enclosed sensing-edge relay controller
FSC-57-115VAC: Enclosed sensing-edge relay controller
Match the whole number.
Manufacturer identifier: FSC-57-115VAC. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 1: Exact model and package · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Power identification · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Edge input group · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Output identification · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Mounting and protection · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Source limitations · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
- RT6 and FSC-57 safety relay controllersRT6_FSC-57_20211111, PDF page 2: Selection boundary · checked 2026-09-14 · RT6_FSC-57_20211111 · Miller Edge
| Exact model and package | FSC-57 packages the RT6 controller in a steel NEMA 13 enclosure with two LEDs and a reset button. Preserve the supply suffix.
|
|---|---|
| Power identification | The exact model option and table specify 115 V AC.
|
| Edge input group | The related-products list explicitly names any model of 4-wire Miller Edge sensing edge. The controller table lists single- or dual-channel inputs.
|
| Output identification | Three normally open outputs and one normally closed output. Exact load and reset configuration require the specific controller documentation.
|
| Mounting and protection | External screw-mounting tabs and a steel NEMA 13 enclosure; the controller and terminal blocks retain separate IP40 and IP20 ratings.
|
| Source limitations | The enclosed model's height/depth figures in inches and millimeters disagree; confirm physical clearance. The temperature row pairs 133 F with 55 C, which are inconsistent. No corrected upper limit is inferred.
|
| Selection boundary | Confirm the exact four-wire edge configuration, supply, required reset behavior and complete safety circuit with a qualified designer. The group match is not an installed-door or current certification approval.
|
Documented fitment & exclusions
Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.
A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.
| Equipment or component / relationship | Evidence and conditions |
|---|---|
| Clima-GUARD Documented compatibility From Clima-GUARD to FSC-57-115VAC. | Clima-GUARD is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MC22 Documented compatibility From MC22 to FSC-57-115VAC. | MC22 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME110 Documented compatibility From ME110 to FSC-57-115VAC. | ME110 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME111 Documented compatibility From ME111 to FSC-57-115VAC. | ME111 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME112 Documented compatibility From ME112 to FSC-57-115VAC. | ME112 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME113 Documented compatibility From ME113 to FSC-57-115VAC. | ME113 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME116 Documented compatibility From ME116 to FSC-57-115VAC. | ME116 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME117 Documented compatibility From ME117 to FSC-57-115VAC. | ME117 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME120 Documented compatibility From ME120 to FSC-57-115VAC. | ME120 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| ME123 Documented compatibility From ME123 to FSC-57-115VAC. | ME123 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MT21 Documented compatibility From MT21 to FSC-57-115VAC. | MT21 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MT22 Documented compatibility From MT22 to FSC-57-115VAC. | MT22 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MT33 Documented compatibility From MT33 to FSC-57-115VAC. | MT33 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MU21 Documented compatibility From MU21 to FSC-57-115VAC. | MU21 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MU22 Documented compatibility From MU22 to FSC-57-115VAC. | MU22 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| MU33 Documented compatibility From MU33 to FSC-57-115VAC. | MU33 is within the exact four-wire Miller Edge input group listed for FSC-57-115VAC. Applies only within this source scope
|
| RT6-115VAC Documented compatibility From RT6-115VAC to FSC-57-115VAC. | The matching-voltage FSC-57 package is explicitly described as an RT6 inside its enclosure. Applies only within this source scope
|
Direct replacement paths
No direct successor for FSC-57-115VAC is verified in this reference.
A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.
Compare exact equipment or a component.
Check a part or accessory pairing
Recall references
No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.
Sources & scope
- Miller Edge Clima-GUARD sensing edgeMiller Edge · US · checked 2026-09-13 · CLIMAGUARD_20220307
- Miller Edge MC22 sensing edgeMiller Edge · US · checked 2026-09-13 · MC22_spec_20260506
- Miller Edge ME110 sensing edgeMiller Edge · US · checked 2026-09-13 · ME110_V7
- Miller Edge ME111 sensing edgeMiller Edge · US · checked 2026-09-13 · ME111_20201218
- Miller Edge ME112 sensing edgeMiller Edge · US · checked 2026-09-13 · ME112_20201218
- Miller Edge ME113 sensing edgeMiller Edge · US · checked 2026-09-13 · ME113_20201218
- Miller Edge ME116 sensing edgeMiller Edge · US · checked 2026-09-13 · ME116_20201218
- Miller Edge ME117 sensing edgeMiller Edge · US · checked 2026-09-13 · ME117_20201218
- Miller Edge ME120 sensing edgeMiller Edge · US · checked 2026-09-13 · ME120_20201218
- Miller Edge ME123 sensing edgeMiller Edge · US · checked 2026-09-13 · ME123_20201218
- Miller Edge MT21 sensing edgeMiller Edge · US · checked 2026-09-13 · MT_20201218
- Miller Edge MU21 sensing edgeMiller Edge · US · checked 2026-09-13 · MU21_20220607
- Miller Edge MU22 sensing edgeMiller Edge · US · checked 2026-09-13 · MU22_20220607
- Miller Edge MU33 sensing edgeMiller Edge · US · checked 2026-09-13 · MU33_20220512
- RT6 and FSC-57 safety relay controllersMiller Edge · US · checked 2026-09-14 · RT6_FSC-57_20211111
Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.
This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.
A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.