Miller Edge / Accessory reference
Miller Edge MIRCU-02: Photo-optic interface with non-monitored output
MIRCU-02: Photo-optic interface with non-monitored output
Match the whole number.
Manufacturer identifier: MIRCU-02. Keep every character when comparing it with your label or paperwork. A similar number does not establish the same component.
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 1: Interface role · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 2: Input and output · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 2: Power and response · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 2: Housing · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 2: Exact compatible systems · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 2: Named included systems · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 2: Identity boundary · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
- Infra-Red Control Unit MIRCU-02MIRCU-02_20210101, PDF page 1: Selection boundary · checked 2026-09-14 · MIRCU-02_20210101 · Miller Edge
| Interface role | Converts a pulsed photo-optic signal to a non-monitored dry-contact output for a permitted legacy or supplementary application.
|
|---|---|
| Input and output | Two-wire pulsed monitored photo-eye input; normally open and normally closed non-monitored outputs.
|
| Power and response | 12-24 V AC/DC; up to 50 mA; nominal 30 ms response.
|
| Housing | Polycarbonate housing, NEMA 4 Class 2 device; 1.75 H x 1.75 W x 6.625 L inches.
|
| Exact compatible systems | The compatible list names MIRM-S2, MIRM-S2-50, MIRM-T2, MIRM-T2-50, MIRM-Z2 and MIRM-Z2-50.
|
| Named included systems | The included-with list separately names MIRF-S2, MIRF-S2-50, MIRF-T2, MIRF-T2-50, MIRF-Z2 and MIRF-Z2-50.
|
| Identity boundary | The drawing caption omits the zero in MIRCU-2; the main heading and revision identify MIRCU-02. No alias or separate product is approved from that caption.
|
| Selection boundary | Confirm that the installed operator permits the exact non-monitored or supplementary application. The device does not preserve a monitored output and must not be treated as a substitute for required monitored entrapment protection.
|
Documented fitment & exclusions
Read the exact equipment or component, market, production and variant limits in every row. An omitted pairing has not been verified by this reference.
A component pairing applies only to the listed items and source conditions. It does not establish suitability for an installed opener or compatibility through another component.
| Equipment or component / relationship | Evidence and conditions |
|---|---|
| LC-K36 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with LC-K36 in the non-monitored LC specification. Applies only within this source scope
|
| LC-K72 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with LC-K72 in the non-monitored LC specification. Applies only within this source scope
|
| MIRF-S2 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with MIRF-S2. Applies only within this source scope
|
| MIRF-S2-50 Documented compatibility From MIRCU-02 to MIRF-S2-50. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with MIRF-S2-50. Applies only within this source scope
|
| MIRF-T2 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with MIRF-T2. Applies only within this source scope
|
| MIRF-T2-50 Documented compatibility From MIRCU-02 to MIRF-T2-50. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with MIRF-T2-50. Applies only within this source scope
|
| MIRF-Z2 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with MIRF-Z2. Applies only within this source scope
|
| MIRF-Z2-50 Documented compatibility From MIRCU-02 to MIRF-Z2-50. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly included with MIRF-Z2-50. Applies only within this source scope
|
| MIRM-S2 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly listed as compatible with MIRM-S2. Applies only within this source scope
|
| MIRM-S2-50 Documented compatibility From MIRCU-02 to MIRM-S2-50. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly listed as compatible with MIRM-S2-50. Applies only within this source scope
|
| MIRM-T2 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly listed as compatible with MIRM-T2. Applies only within this source scope
|
| MIRM-T2-50 Documented compatibility From MIRCU-02 to MIRM-T2-50. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly listed as compatible with MIRM-T2-50. Applies only within this source scope
|
| MIRM-Z2 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly listed as compatible with MIRM-Z2. Applies only within this source scope
|
| MIRM-Z2-50 Documented compatibility From MIRCU-02 to MIRM-Z2-50. | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. MIRCU-02 is explicitly listed as compatible with MIRM-Z2-50. Applies only within this source scope
|
| MLC-K36 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. The MLC sheet explicitly names MIRCU-02 as its interface to a non-monitored configuration. Applies only within this source scope
|
| MLC-K72 Documented compatibility | Conditional Additional source conditions or an adapter must be checked before confirming compatibility. Details still needed
Use the exact label and the source scope below. An unanswered condition keeps this result conditional or unverified. The MLC sheet explicitly names MIRCU-02 as its interface to a non-monitored configuration. Applies only within this source scope
|
Direct replacement paths
No direct successor for MIRCU-02 is verified in this reference.
A direct replacement statement does not establish reverse interchangeability, a kit equivalent or a later replacement chain.
Compare exact equipment or a component.
Check a part or accessory pairing
Recall references
No recall reference is included for this identifier in the published dataset. This is not a safety clearance or proof that no recall exists.
Sources & scope
- Non-Monitored Light Curtain LC-K36 and LC-K72Miller Edge · US · checked 2026-09-14 · LC-K36-K72_20210101
- Infra-Red Control Unit MIRCU-02Miller Edge · US · checked 2026-09-14 · MIRCU-02_20210101
- Monitored Light Curtain MLC-K36 and MLC-K72Miller Edge · US · checked 2026-09-14 · MLC-K36-K72_20240515
- Rebel thru-beam photo-eye systemsMiller Edge · US · checked 2026-09-14 · Rebel_20210101
- Patriot-2 Telescopic traveling thru-beam photo-eye systemsMiller Edge · US · checked 2026-09-14 · MIRT2_20210101
- Patriot-2 Z-Flap traveling thru-beam photo-eye systemsMiller Edge · US · checked 2026-09-14 · MIRZ2_20210101
Anderson prepared this reference from the listed evidence. Source statements are not an Anderson installation inspection or independent product test. Official documents stay on their publisher’s website.
This is an independent Anderson reference. Manufacturer names identify the equipment and do not imply affiliation or authorized-dealer status. Anderson provides repair service in its listed Connecticut communities.
A reference listing does not establish current stock, a price, eligibility for manufacturer support or that a component is faulty.